GE Kelman Transport X2 Dissolved Gas Analysis

$12,275.00

The GE Kelman Transport X2 Dissolved Gas Analysis Analyzer is a portable transformer-oil testing instrument designed for field-based dissolved gas analysis and transformer condition assessment. It helps maintenance professionals identify gas patterns associated with potential thermal and electrical faults and supports predictive maintenance and transformer diagnostics.

Description

GE Kelman Transport X2 Dissolved Gas Analysis (DGA) Analyzer – Portable Transformer Oil Condition Monitoring System

The GE Kelman Transport X2 Dissolved Gas Analysis (DGA) Analyzer is a portable instrument designed for analyzing dissolved gases in transformer oil and assessing the condition of oil-filled electrical power equipment.

DGA is widely used for detecting early signs of transformer faults by measuring gases generated by electrical and thermal stresses within insulating oil. The Transport X2 is designed to provide field-based analysis, allowing maintenance teams to perform testing without necessarily sending oil samples to an external laboratory.

The system is suitable for transformer condition assessment, fault diagnosis, maintenance planning and predictive maintenance in electrical power-generation, transmission and distribution environments.

Main Benefits

Portable dissolved gas analysis
Designed for transformer oil testing
Field-based transformer condition assessment
Helps identify developing electrical and thermal faults
Rapid on-site analysis
Suitable for preventive and predictive maintenance
Supports transformer fault diagnosis
Reduces reliance on laboratory-only testing
Designed for power-generation and transmission environments
Portable design for field service teams

Key Features

Dissolved Gas Analysis
The Transport X2 is designed to measure dissolved gases in transformer insulating oil. DGA results can provide valuable information about abnormal conditions developing inside oil-filled electrical equipment.

Transformer Fault Diagnosis
Dissolved gases can be associated with different fault conditions, including:
Thermal faults
Partial discharge
Arcing
Overheating
Insulation degradation

DGA results should be interpreted using appropriate industry standards and diagnostic methods.

Portable Field Testing
The Transport X2 is designed for use directly at transformer sites, allowing technicians to perform analysis as part of routine maintenance and troubleshooting programs.

Condition Monitoring
Regular DGA measurements can help establish trends over time. Changes in dissolved-gas concentrations can provide an early indication that further investigation or maintenance may be required.

Industrial Power Applications
The system is intended for oil-filled electrical equipment used in demanding power-system environments.

Key Specifications

Brand: GE / GE Digital Energy / Kelman
Model: Transport X2
Product Type: Portable Dissolved Gas Analysis (DGA) Analyzer
Primary Application: Transformer Oil Analysis
Technology: Dissolved Gas Analysis
Measurement Purpose: Transformer condition monitoring and fault diagnosis
Sample Type: Transformer insulating oil
Typical Equipment: Oil-filled power transformers and related electrical equipment
Analysis: Dissolved-gas measurement
Testing Environment: Field and on-site transformer maintenance
Operation: Portable
Typical Users: Transformer service engineers, utility maintenance teams and electrical power professionals
Typical Applications: Transformer diagnostics, predictive maintenance, condition assessment and troubleshooting

Applications

The GE Kelman Transport X2 is suitable for:
Transformer oil testing
Dissolved gas analysis
Transformer condition monitoring
Transformer fault diagnosis
Predictive maintenance
Preventive maintenance
Power transformer inspection
Electrical equipment diagnostics
Power-generation maintenance
Transmission-system maintenance
Distribution-system maintenance
Field troubleshooting
Typical Users
Electrical utilities
Transformer maintenance teams
Power-generation companies
Transmission operators
Distribution companies
Transformer service contractors
Electrical testing laboratories
Condition-monitoring specialists

Package includes:
1x GE Kelman Transport X2 unit
1x ground glass syringe
1x 50-ml syringe
1x three-way plastic stopcock
1x bottle lid assembly
1x magnet retriever
1x quick connection valve
2x teflon coated stir bars
8x replacement Teflon filters
3x sample bottles
1x power cable
6-month warranty

Fully tested and serviced by GE authorized, set up ready to working order and works flawlessly with GE working standards.

What is the GE Kelman Transport X2 used for?
The Transport X2 is used for dissolved gas analysis of transformer insulating oil to support transformer condition monitoring and fault diagnosis.

Why is dissolved gas analysis important?
DGA can provide early indications of abnormal thermal or electrical activity occurring inside oil-filled transformers, helping maintenance teams investigate potential problems before they develop into more serious failures.

Can the Transport X2 be used in the field?
Yes. Its portable design is intended for on-site transformer testing and maintenance applications.

What equipment can be tested?
It is primarily intended for oil-filled power transformers and related oil-insulated electrical equipment.

Is the Transport X2 a laboratory analyzer?
It is designed specifically for portable field-based DGA, making it useful when testing needs to be performed directly at the transformer site.