Fluke 1760 TR US Three-Phase Power Quality Recorder
The Fluke 1760 TR US Three-Phase Power Quality Recorder Topas is a high-performance Analytical Instrument designed for advanced electrical power quality monitoring, troubleshooting, and compliance testing. It provides precise three-phase power analysis with IEC 61000-4-30 Class A compliance, making it suitable for industrial facilities, utilities, and critical power systems.
The Fluke 1760 TR US captures detailed voltage, current, power, harmonics, transients, and power disturbances, helping engineers identify electrical problems, improve system reliability, and verify power quality standards.
Description
Fluke 1760 TR US Three-Phase Power Quality Recorder Topas – Advanced Class A Power Quality Analyzer for Industrial Electrical Testing
The Fluke 1760 TR US Three-Phase Power Quality Recorder Topas is a professional Analytical Instrument designed for advanced electrical power quality testing and industrial energy analysis. With IEC 61000-4-30 Class A compliance, the recorder delivers highly accurate measurements for troubleshooting, compliance testing, and preventive maintenance.
The system continuously records important electrical parameters including voltage, current, power, harmonics, flicker, frequency, and transient events. Its fast transient capture capability, GPS synchronization, multiple input channels, and PQ Analyze software make it a powerful solution for identifying electrical disturbances and improving system reliability.
The Fluke 1760 TR US Three-Phase Power Quality Recorder Topas is ideal for electrical engineers, utilities, industrial maintenance teams, and professionals requiring accurate and reliable power quality measurement technology.
Main Benefits
Advanced Power Quality Analysis
Measures and records detailed electrical parameters for accurate diagnosis of power system performance.
IEC 61000-4-30 Class A Compliance
Provides reliable measurement results for demanding power quality testing and compliance verification.
Detects Electrical Disturbances
Captures voltage dips, swells, interruptions, harmonics, flicker, imbalance, and transient events.
High-Speed Transient Recording
Records fast transient events up to 10 MHz for detailed fault investigation.
Industrial-Grade Reliability
Designed for demanding environments including power plants, manufacturing facilities, and utility applications.
Key Features
Three-Phase Power Quality Recording
Supports detailed monitoring of three-phase electrical systems with multiple voltage and current inputs.
Class A Power Quality Measurement
Meets strict international requirements for accurate power quality analysis.
8 Input Channels
Includes configurations for:
4 voltage channels + 4 current channels
8 voltage channels
depending on measurement requirements.
Harmonic & Interharmonic Analysis
Measures voltage and current harmonics up to the 50th order, including total harmonic distortion (THD).
Fast Transient Capture
Provides high-frequency transient recording capability for identifying short-duration electrical disturbances.
GPS Time Synchronization
Allows accurate event correlation across multiple measurement locations.
PQ Analyze Software
Provides data analysis, reporting, and detailed evaluation of recorded power quality events.
Large Data Storage
Includes internal 2 GB flash memory for extended monitoring sessions.
Portable Industrial Design
Built for field measurement with a rugged enclosure suitable for professional electrical testing.
Specifications
Product Type: Three-Phase Power Quality Recorder
Category: Analytical Instrument
Subcategory: Power Quality Analyzers
Manufacturer: Fluke
Measurement Functions:
Voltage measurement
Current measurement
Active, reactive, and apparent power
Power factor
Energy measurement
Frequency
Flicker
Voltage imbalance
Harmonics and interharmonics
THD analysis
Power events recording
Compliance:
IEC 61000-4-30 Class A
Input Channels:
8 channels
4 voltage / 4 current configuration
8 voltage configuration option
Transient Recording:
Up to 10 MHz transient analysis
Memory:
2 GB internal flash memory
Current Measurement:
Flexible current probes
1000 A / 200 A AC ranges
Voltage Inputs:
600 V international configuration
1000 V US configuration
Connectivity:
Ethernet
RS-232 communication
Included Accessories:
Voltage probes
Flexible current clamps
GPS synchronization receiver
PQ Analyze software
Carrying case
Applications
Industrial Power Monitoring
Analyzes electrical systems in factories and manufacturing plants to maintain reliable operation.
Utility Power Quality Testing
Supports power distribution analysis and compliance verification.
Electrical Fault Troubleshooting
Helps identify causes of equipment failures caused by voltage disturbances, harmonics, or transients.
Energy System Analysis
Evaluates electrical efficiency, power consumption, and system performance.
Preventive Maintenance
Provides long-term monitoring data to prevent unexpected electrical problems.
Critical Infrastructure Testing
Suitable for hospitals, data centers, commercial buildings, and large electrical installations.
What is the Fluke 1760 TR US Power Quality Recorder used for?
It is used for professional three-phase electrical power quality monitoring, troubleshooting, and compliance testing.
Is Fluke 1760 TR Class A compliant?
Yes. It meets IEC 61000-4-30 Class A requirements for advanced power quality measurements.
What problems can the Fluke 1760 detect?
It can detect voltage dips, swells, interruptions, harmonics, flicker, imbalance, and transient disturbances.
Can it record electrical transients?
Yes. The TR version supports fast transient recording up to 10 MHz.
Is Fluke 1760 suitable for industrial environments?
Yes. It is designed for utilities, industrial facilities, and advanced electrical measurement applications.
What software is used with the Fluke 1760?
The recorder works with Fluke PQ Analyze software for data analysis and reporting.